Certificate of Analysis · GLOW 70 mg Blend · Certificate reference 70-0807
This certificate covers Elyria Bio's GLOW 70 mg Blend, certificate reference 70-0807, tested by ILS Laboratories on 2026-11-12: purity 99.90% by RP-HPLC at 214 nm (laboratory specification ≥95.0%). The certificate reports identity (HPLC retention time vs. reference standard): BPC-157, GHK-Cu, TB-4 (thymosin beta-4, supplied as TB-500), Confirmed; net content (assayed): 72.41 mg (laboratory specification Report Only); endotoxin (USP <85>): 0.16 EU/mL (Reported); sterility (PCR): No Growth (PASS).
COA # COA-2026-7RL-V0 · certificate reference 70-0807 (printed on the certificate as Lot Number).
Independent third-party testing by ILS Laboratories, San Diego, CA, on one certificate covering purity, identity, endotoxin and sterility. The certificate links to the laboratory's verification portal.
Product: GLOW 70 mg Blend · 70 mg
Laboratory: ILS Laboratories, 8222 Vickers St Suite 106, San Diego CA 92111
The laboratory's portal shows this certificate at its verify link; the access code is printed on the certificate.
Certificate of analysis — full panel (RP-HPLC at 214 nm; identity by HPLC retention time vs. reference standard)
Report COA-2026-7RL-V0Tested 11/12/2026
- Purity · RP-HPLC at 214 nm
- 99.90% (laboratory specification ≥95.0%)
- Identity · HPLC retention time vs. reference standard
- BPC-157, GHK-Cu, TB-4 (thymosin beta-4, supplied as TB-500), Confirmed
- Labelled content
- 70 mg (vial label)
- Net content (assayed)
- 72.41 mg (laboratory specification Report Only)
- On the assayed figure
- Reported as Net Blend Peptide Content against a Report Only specification; the certificate sets no acceptance range.
- Volume
- 3 mL
- Appearance
- Good
- Sample matrix
- Lyophilized
- Date received
- 11/06/2026
- Accession #
- ACC-2026-25424
- Fentanyl screen
- Not Detected (laboratory specification Immunoassay, 50 ng/mL cutoff) (PASS)
- Net blend peptide content — GHK-cu
- 51.52 mg
- Net blend peptide content — BPC-157
- 10.40 mg
- Net blend peptide content — TB-4
- 10.49 mg
- On the per-component figures
- Per-component content determined by individual peak integration. Not all labeled components may be present.
- Heavy metals — Arsenic (As) · ICP-MS
- Not Detected (laboratory specification NMT 1.5 ppm) (PASS)
- Heavy metals — Cadmium (Cd) · ICP-MS
- Not Detected (laboratory specification NMT 0.5 ppm) (PASS)
- Heavy metals — Chromium (Cr) · ICP-MS
- 0.0906 ppm (laboratory specification NMT 10 ppm) (PASS)
- Heavy metals — Mercury (Hg) · ICP-MS
- 0.0717 ppm (laboratory specification NMT 1.5 ppm) (PASS)
- Heavy metals — Lead (Pb) · ICP-MS
- 0.0714 ppm (laboratory specification NMT 1 ppm) (PASS)
- On the heavy-metals figures
- Elemental impurities analyzed by ICP-MS per USP <233> methodology. Acceptance criteria are internal laboratory quality screening limits for research-use materials and do not represent evaluation against any specific pharmacopeial monograph or product specification.
Verify this certificate with the laboratory at portal.ils-lab.com using access code RUK9TYRR. That confirms the document is genuine and was issued by them. It confirms the certificate, not your individual vial.
The laboratory’s PDF of report COA-2026-7RL-V0Endotoxin and sterility, on the same certificate
Endotoxin (USP <85>): 0.16 EU/mL (Reported)Sterility (PCR): No Growth (PASS)
About the laboratories: who tests our lots, the methods each uses and how to verify a certificate.
Notes on reading this certificate: How to read a peptide certificate of analysis, row by row; How to verify a certificate with the laboratory: the ILS portal, step by step; “Report Only” and net peptide content: why a certificate can show 10.7 mg on a 10 mg label; Endotoxin (USP <85>) and sterility: why they are on some panels and not others; HPLC retention time vs FTIR for identity: what our two laboratories do differently.
For Research Use Only. Not for human consumption.
Last updated: