“Report Only” and net peptide content: why a certificate can show 10.7 mg on a 10 mg label
“Report Only” means the laboratory measured the value and set no pass or fail limit on it. Net peptide content is the mass of the peptide itself in the sample, not its purity. A figure above the label, such as 10.7 mg on a 10 mg label, is what was measured; the certificate passes no judgement on it.
The example in this note is real. The ILS Laboratories certificate for our BPC-157, certificate reference 030284, reports a net peptide content of 10.7 mg for a vial labelled 10 mg, and its specification column for that row reads "Report Only". It is linked as a PDF from the product page. Here is what each part of that row means, and what it does not.
What does “Report Only” mean on a certificate?
It means the laboratory measured the value and set no acceptance criterion for it, so the figure carries no pass or fail.
Every row on a certificate has three parts: a test, a method and a criterion. ICH Q6B defines a specification as "a list of tests, references to analytical procedures, and appropriate acceptance criteria which are numerical limits, ranges, or other criteria for the tests described"[1]. Most rows carry a criterion you can read the figure against: a purity row says ≥ some percentage; a sterility row says no growth.
A "Report Only" row is a test without a criterion. The laboratory performs the measurement and prints the figure, and deliberately does not say whether it passes, because no limit was set for it. On the 030284 certificate our record of the row says: Reported as Net Peptide Content against a Report Only specification; the certificate sets no acceptance range.
That is why we publish such a figure as it is printed, and never describe it as "meeting" anything. Our testing standard says the same: "Report Only" is a measurement, not a pass, and net peptide content is not part of our release standard, which is the purity floor (≥99% HPLC purity) and the identity method the laboratory reports.
What is net peptide content?
Net peptide content is the mass of the peptide itself in the sample, as distinct from the mass of everything in the vial.
A lyophilised peptide is rarely only peptide. Synthetic peptides commonly carry counter-ions, such as trifluoroacetate left from synthesis or purification[3]; the dried powder can hold residual water; and a vial can contain excipients added on purpose. All of these add weight. None of them is the peptide.
ICH Q6B describes this attribute as quantity: "a physicochemical measure of protein content", "expressed in mass", determined "using an appropriate assay, usually physicochemical in nature"[1]. One classical way to measure it is amino acid analysis: the peptide bonds are hydrolysed, and the freed amino acids are separated, detected and quantified[2]. The amount of each amino acid, set against the peptide's known sequence, gives the amount of peptide. Other assays, such as a calibrated chromatographic assay against a reference standard, answer the same question by a different route. The pharmacopoeias treat this "assay" of content as its own family of tests, separate from identification and purity[4].
How is content different from purity?
They answer different questions, on different scales.
- Purity is a ratio within a chromatogram: the target peptide's share of the peptide-related signal at one wavelength. For 030284 it is 99.72%, by RP-HPLC at 214 nm.
- Content is a mass: how many milligrams of peptide the sample holds. For 030284 it is 10.7 mg.
A sample can be chromatographically very pure and still hold less peptide per vial than its label, if counter-ions, water or excipients make up much of the powder. And a sample's content can sit above the label while its purity is unchanged. The two rows never stand in for each other, which is why HPLC purity vs identity treats content as a separate question.
How can a vial hold more peptide than its label says?
A vial can hold more because its label is a nominal target, and a measured sample from the batch can land on either side of it.
The label states the amount the vial is meant to hold. A measurement of one sample from the batch can land on either side of it, for reasons that have nothing to do with error:
- The label is a nominal figure. It names the target amount, not a measured one.
- Filling is not exact. Any filling process varies around its target.
- Every assay has its own uncertainty. A content assay reports one measurement of one sample, not the batch's true mean.
A laboratory that does set a criterion for content can allow for this with a window around the label. The BTLabs certificate for our SS-31, certificate reference 060722, prints its potency specification as "90 – 110 % of 10 mg" and reports 10.4 mg (104.5 %). The window itself says that a content above the label is expected to occur. On a "Report Only" row the same kind of figure simply appears without a window beside it.
So 10.7 mg on a 10 mg label is a measurement of one sample. It is not an extra amount, and it is not a defect. It is what that laboratory found in that sample by that method.
Why do laboratories treat the content row differently?
There is no single convention to follow. The pharmacopoeias treat assay of content as its own family of tests beside identification and purity, and they do not agree on how it should be specified[4]. A specification, in ICH Q6B's terms, pairs each test with an acceptance criterion: a numerical limit, a range, or some other criterion[1]. A certificate can therefore carry a content row with a criterion, as the 060722 certificate does ("90 – 110 % of 10 mg"), or one without, as the 030284 certificate does ("Report Only").
The practical consequence is simple. Before you compare a content figure with anything, read three things on its row: the method, the criterion if there is one, and the labelled content it was measured against. A figure read without those three is a number without a scale.
What do our lots' certificates show?
The table below is generated from every released lot whose certificate prints both a labelled content and an assayed content. Each figure and each specification is printed exactly as the lot's certificate prints it. Where a certificate prints a window, the window is shown beside the figure; this table does not judge any figure against it.
| Product | Certificate reference | Laboratory | Labelled content | Assayed content, as printed | Specification, as printed |
|---|---|---|---|---|---|
| BPC-157 | 030284 | ILS Laboratories | 10 mg | 10.7 mg | Report Only |
| TB-500 | 030371 | ILS Laboratories | 10 mg | 10.6 mg | Report Only |
| MOTS-c | 050550 | ILS Laboratories | 20 mg | 20.84 mg | Report Only |
| GLP-3 | 050575 | ILS Laboratories | 15 mg | 15.25 mg | Report Only |
| GLP-3 | 100702 | ILS Laboratories | 10 mg | 10.24 mg | Report Only |
| GLP-3 | 300816 | ILS Laboratories | 30 mg | 31.51 mg | Report Only |
| GLP-3 | 500730 | ILS Laboratories | 50 mg | 52.62 mg | Report Only |
| KLOW Blend | 050591 | ILS Laboratories | 80 mg | 82.46 mg | Report Only |
| SS-31 | 060722 | BTLabs | 10 mg | 10.4 mg (104.5 %) | 90 – 110 % of 10 mg |
| Tesamorelin | 060738 | BTLabs | 10 mg | 12.2 mg (121.8 %) | 90 – 110 % of 10 mg |
| GLP-2 | 070915 | BTLabs | 30 mg | 32 mg (106.7 %) | 90 – 110 % of 30 mg |
| Glutathione | 26040901 | ILS Laboratories | 1500 mg | 1551.34 mg | Report Only |
| GLOW 70 mg Blend | 70-0807 | ILS Laboratories | 70 mg | 72.41 mg | Report Only |
| Thymosin Alpha-1 | TA10701 | ILS Laboratories | 10 mg | 10.53 mg | Report Only |
Two patterns are visible in the table. The ILS Laboratories rows read "Report Only", while the BTLabs rows print a window around the label. And because each laboratory measures content by its own method, against its own criterion or none, a figure from one is not directly comparable with a figure from the other.
What does the content row not tell you?
The content row does not tell you the amount in your own vial, a verdict, or anything about purity, identity or microbial quality.
- It is not the amount in your vial. It is the amount measured in the sample the laboratory received. Our vials are not individually lot-numbered, so no certificate can be matched to one vial (our testing standard explains this).
- It is not a verdict. On a "Report Only" row the laboratory has made none, and we do not add one.
- It says nothing about purity, identity or microbial quality. Those are separate rows, explained in how to read a certificate of analysis and endotoxin and sterility.
Every released lot's content row is published on its product page and on the certificates page, and the laboratories page lists which laboratory tested which lot.
Every figure on this page that describes an Elyria Bio lot is generated from the same certificate records that feed the product pages and the certificates page, and is read from the laboratory’s own certificate. What a lot must meet before release is set out in our testing standard; who tests our lots, and how, is on the laboratories page. Any other statement of fact cites its source in the list below.
All Elyria Bio products are Research Use Only (RUO) in-vitro laboratory reference materials. They are not for human or veterinary consumption and are not drugs, foods, cosmetics, or dietary supplements. Nothing on this site is medical advice or a dosing recommendation. Purchasing or using these materials in any way that violates this policy or applicable law is strictly prohibited.
Sources
- ICH Q6B: Specifications: Test Procedures and Acceptance Criteria for Biotechnological/Biological Products. International Council for Harmonisation (ICH). Link and title checked 2026-10-23.
- Amino acid analysis (Curr Protoc Protein Sci, 2009). Rutherfurd SM, Gilani GS; PubMed 19937719. Link and title checked 2026-10-23.
- Related impurities in peptide medicines (J Pharm Biomed Anal, 2014). D'Hondt M, Bracke N, Taevernier L, et al.; PubMed 25044089. Link and title checked 2026-10-23.
- Quality specifications for peptide drugs: a regulatory-pharmaceutical approach (J Pept Sci, 2009). Vergote V, Burvenich C, Van de Wiele C, De Spiegeleer B; PubMed 19750489. Link and title checked 2026-10-23.